POSTOPERATIVE ATRIAL MONITORING

A clearer atrial signal, continuously at the bedside

AtriAmp connects temporary atrial pacing wires to a compatible bedside monitor, providing continuous access to intra-cardiac atrial signals while supporting pacing when needed.

Surface ECG may not show the full rhythm story

THE CLINICAL CHALLENGE

Following cardiac surgery, identifying atrial activity can be difficult when P waves are small, obscured or difficult to distinguish on the surface ECG. Atrial electrograms can provide additional information to help clinicians differentiate postoperative rhythms, but conventional acquisition methods may offer only a brief view of the atrial signal.⁴,⁵,⁷

 

50-60 %

of patients with congenital heart disease may experience an arrhythmia following cardiac surgery¹

CONTINUOUS ATRIAL ELECTROGRAMS

Continuous access to the atrial signal

AtriAmp connects temporary atrial pacing wires to a compatible bedside ECG monitor, making the atrial electrogram continuously available alongside the surface ECG. When pacing is needed, AtriAmp also supports connection to a compatible external pacemaker.³,⁴

 

Monitor continuously. Pace when needed.

AtriAmp brings the atrial signal into the existing bedside monitoring environment without requiring a separate monitor.³

Greater accuracy and confidence in postoperative rhythm identification

In a prospective observational study, 88 pediatric cardiology and critical-care providers evaluated postoperative rhythms using surface ECG alone and the same rhythms with an atrial electrogram obtained through AtriAmp. Access to the AtriAmp signal significantly increased the accuracy and confidence of provider rhythm identification.¹

Increased Accuracy

Provider rhythm-identification accuracy increased significantly with the AtriAmp signal compared with surface ECG alone.¹

Increased Confidence

Provider confidence increased significantly when interpreting rhythms with the AtriAmp signal.¹

The most significant increases in diagnostic accuracy were observed for junctional ectopic tachycardia, sinus tachycardia and complete heart block.¹

In a separate qualitative study of 14 early adopters in a pediatric intensive care unit, clinicians described accelerated time from an arrhythmia event to diagnosis and treatment, greater confidence and improved education about postoperative arrhythmias. These findings reflect provider perceptions and were not measured as comparative clinical outcomes.²

Bring the atrial signal to the monitor already at the bedside

HOW ATRIAMP WORKS

AtriAmp acts as a connection hub between temporary atrial pacing wires, a compatible bedside ECG monitor and, when needed, an external pacemaker. This makes the atrial electrogram continuously available on the bedside monitor while allowing simultaneous pacing.³

1

Connect the atrial pacing wires

Attach the patient’s temporary atrial pacing wires to AtriAmp.
2

Connect the bedside monitor

Connect AtriAmp to a compatible Type CF, defibrillation-proof ECG monitor through a unipolar precordial lead.
3

View the atrial signal continuously

Display the atrial electrogram on the bedside monitor, with connection to an external pacemaker available when pacing is needed.

DESIGNED FOR POSTOPERATIVE CARE

Continuous atrial information without another monitor

AtriAmp makes an additional atrial signal available within the bedside monitoring environment already used by the care team.

Continuous visibility

Keeps the atrial electrogram available on the bedside monitor instead of limiting access to a short, manually acquired tracing.

Monitoring and pacing

Supports continuous atrial-signal monitoring while maintaining connection to a compatible external pacemaker when pacing is needed.

Bedside access

Makes the atrial signal available to the multidisciplinary team where postoperative monitoring and clinical decisions occur.

PRODUCT DETAILS

Designed to integrate with standard postoperative cardiac equipment

AtriAmp is a sterile, single-patient-use device designed to connect cardiac pacing leads to a compatible bedside ECG monitor and/or external pacemaker. Device operation was evaluated for use for up to 14 days.⁶ Refer to the Instructions for Use for complete indications, compatibility requirements, warnings and instructions.

Monitor requirement

Type CF, defibrillation-proof ECG monitor using a unipolar precordial chest lead V1–V6.

Pacing support

Connects cardiac pacing leads with a compatible external pacemaker using the appropriate interface cable.

Use

Sterile and single-patient use.

Evaluated duration

Up to 14 days.

CLINICAL AND PRODUCT RESOURCES

  • Explore the evidence behind AtriAmp
  • Clinical Evidence Summary
  • Accuracy and confidence study
  • Early adoption study
  • Product Data Sheet
  • Instructions for Use

POSTOPERATIVE ATRIAL MONITORING

Bring continuous atrial information to the bedside

Learn how AtriAmp can support postoperative rhythm identification within your cardiac-care program.


Indications for Use  The AtriAmp supports pacing by acting as an extension cable between an external pacemaker and cardiac pacing leads. The AtriAmp also supports monitoring of intra-cardiac signals by transmitting signals to one of the unipolar precordial chest leads (leads V1–V6) of a Type CF, defibrillation-proof ECG monitor. Prescription use only.


 

1

rown DH, Zhang X, Al-Subu AM, Von Bergen NH. Improvements in Accuracy and Confidence in Rhythm Identification After Cardiac Surgery Using the AtriAmp Signals. Journal of Intensive Care Medicine. 2023;38(9):809–815. doi:10.1177/08850666231164613 Source

2

 Leopold SM, Brown DH, Zhang X, et al. Early Impressions and Adoption of the AtriAmp for Managing Arrhythmias Following Congenital Heart Surgery. Pediatric Cardiology. Published online 2024. doi:10.1007/s00246-024-03526-x Source

3

Somasundaram N, Boadu JK, Von Bergen NH. First-in-human use of a continuous real-time atrial electrogram monitoring device after cardiac surgery. HeartRhythm Case Reports. 2021;7(4):251–254. Source

4

Peotter AM, Brown DR, Kalscheur MM, Von Bergen NH. Atrial Electrography for Postoperative Tachyarrhythmia Analysis in Patients. Journal of Innovations in Cardiac Rhythm Management. 2021;12(10):4726–4743. doi:10.19102/icrm.2021.121003 Source

5

Sandau KE, Funk M, Auerbach A, et al. Update to Practice Standards for Electrocardiographic Monitoring in Hospital Settings. Circulation. 2017;136(19):e273–e344. doi:10.1161/CIR.0000000000000527 Source

6

U.S. Food and Drug Administration. 510(k) Premarket Notification K200674. AtriAmp. Decision date July 2, 2020. Source

7

McRae ME, Chan A, Imperial-Perez F. Cardiac surgical nurses’ use of atrial electrograms to improve diagnosis of arrhythmia. American Journal of Critical Care. 2010;19(2):124–133. doi:10.4037/ajcc2010215 Source